Solar System with Inverter Integrated (All-in-one system)

BFB-51100AH-048005-5KW


Product introduction

BFB series products is a kind of new hybrid photovoltaic energy system that combines solar energy storage, city charge, and AC sine wave output into one system. It adopts the DSP control technology. Through advanced control algorithm, it has the characteristics of high response speed, high reliability and high industrialization standard. There are 4 charge modes available: solar power only, city power priority, solar power priority and mains solar power; Inverter and mains power can be selected to meet different application requirements



  

 

Product characteristic

 

1.   Adopt full digital voltage and current double closed loop control, advanced SPWM technology, and output pure sine wave

2.   It has two output modes of AC bypass and inverter output, and has the function of uninterrupted power supply.

3.   There are 4 modes selectable: Solar power only, city power priority, solar power priority and hybrid charge. 

4.   LCD screen indication, dynamic display of system and operation status.

5.   Has power saving mode to reduce no-load loss.

6.   Intelligent adjustable speed fan is used to dissipate heat efficiently and prolong the service lifepo4 of the system.

7.   Has multiple protection functions and 360 ° all-round protection.

8. Has complete short circuit protection, overvoltage and undervoltage protection, overload protection, reverse irrigation protection, etc.


 



1

LCD Screen


8

RS485 communication port

2

Indication light


9

USB port

3

Light touch button


10

DC12V output

4

On/off switch


11

USB output

5

SOC indicator


12

AC output

6

AC input/outputPV input


13

Circuit breaker

7

DRY contact terminal





Specification


City Power Mode

City Power charge


Rated   input voltage

220/230Vac

Max charge current (Adjustable)

60A

Input   voltage rage

(170Vac~280Vac) ±2%

(90Vac-280Vac2%

Charging   current error

± 5Adc

Frequency

50Hz/ 60Hz  (Automatic detecting)

Charging   voltage range

40 –   58Vdc

Frequency   range

47±0.3Hz ~ 55±0.3Hz (50Hz);

57±0.3Hz ~ 65±0.3Hz (60Hz);

Short   circuit protection

Circuit   breaker and fuse

Overload/short circuit protection

Circuit   breaker

Circuit   breaker specification

40A

Efficiency

>95%

Overcharge protection

Alarm   and turn off charging after 1 minute

Conversion   time (bypass and inverter)

10ms   (Typical)

Maximum charging current   (settable)

60A

AC back irrigation   protection

yes



Maximum bypass overload current

40A



Inverter mode

Solar power charge


Output   voltage waveform

Pure   sine wave

Maximum   PV open circuit voltage

145Vdc

Rated output power

5000 (VA)

PV  Operating voltage range

60-145Vdc

Power   factor

1

MPPT voltage   range

60-115Vdc

Rated output voltage

230Vac

Battery   voltage range

40-60Vdc

Output   voltage error

±5%

Maximum input power

4400W

Output frequency range

50Hz   ± 0.3Hz

60Hz ± 0.3Hz

Solar charging current   range (settable)

0-80A

Efficiency

>92%

Charging   short-circuit protection

Blow   Fuse

Over load protection

(102%<load<125%)   ±    10%:  Error is reported and output is closed   after 5 minutes;                               (125%<load<150%) ±      10%:  Error is reported and   output is closed after 10 seconds;

load>150%   ±10%:               Error is reported   and the output is closed after 5 seconds

Wiring   protection

Reverse   connection protection

Peak   power

10000VA

Maximum   hybrid charging current ( PV+AC)


On load motor capacity

4HP

Maximum hybrid charging   current (settable)

0-140A

Output   short-circuit protection

Circuit   breaker

Other   specification


Specification   of bypass circuit breaker

40A

Operating   temperature range

-15°C to 55°C

Rated battery input voltage

48V (  Minimum starting voltage  44V)

Storage   temperature range

-25°C ~ 60°C

Battery   capacity

5120Wh

Humidity   range

5% to 95% ( Three proofing paint   protection)

Battery   voltage range

40.0Vdc~60Vdc ± 0.6Vdc ( Under voltage alarm  /  Shutdown voltage  /  Overvoltage alarm /  Overvoltage recovery …LCD screen can set data)

Noise

≤60dB

Power   saving mode

Load≤50W

Communication   interface

USB/RS485(WiFi/GPRS)/DRY   contact port